Home > Products > Water Pump > Fire Fighting Pump System 40- 3000m3 /H Flow Range for Sales
                                    Fire Fighting Pump System 40- 3000m3 /H Flow Range for Sales
                                    • Fire Fighting Pump System 40- 3000m3 /H Flow Range for SalesFire Fighting Pump System 40- 3000m3 /H Flow Range for Sales
                                    • Fire Fighting Pump System 40- 3000m3 /H Flow Range for SalesFire Fighting Pump System 40- 3000m3 /H Flow Range for Sales
                                    • Fire Fighting Pump System 40- 3000m3 /H Flow Range for SalesFire Fighting Pump System 40- 3000m3 /H Flow Range for Sales
                                    • Fire Fighting Pump System 40- 3000m3 /H Flow Range for SalesFire Fighting Pump System 40- 3000m3 /H Flow Range for Sales

                                    Fire Fighting Pump System 40- 3000m3 /H Flow Range for Sales

                                    Fire Fighting Water Supply Equipment with Diesel Pump Pump Introduction:Fire Dual-power Water Supply Unit with Diesel and Electric Pump, IS series single-stage, S, SOW series of new single-stage & dual-stage, TSWA, D series. Domestic or foreign diesel engines used have compact structure, easy to......

                                    Send Inquiry

                                    Product Description

                                    Fire Fighting Water Supply Equipment with Diesel Pump
                                     

                                    Pump Introduction:
                                    Fire Dual-power Water Supply Unit with Diesel and Electric Pump, IS series single-stage, S, SOW series of new single-stage & dual-stage, TSWA, D series. Domestic or foreign diesel engines used have compact structure, easy to maintain and use, automatic control, reliable.
                                     
                                    Features:
                                    a)Compact structure
                                    b)Stable running, low noise
                                    c)No leakage
                                    d)Convenient operation
                                    e)Viewing from the inlet of the pump, the outlet of it can
                                    be mounted in one of the three ways, horizontally leftward,
                                    vertically upward and horizontally rightward
                                     
                                    Fire Fighting Pump System 40-3000m3/H Flow Range for Sales
                                    Application:
                                    a)Water supply for the fixed-fighting system of both industrial and civil builtings
                                    b)Fire hydrant fire-extinguishing system
                                     c)Automatic spraying fire-extinguishing system
                                     d)Fog-spraying fire-extinguishing system etc
                                     
                                    Conditions:
                                    Flow range: 40-3000m3/h
                                    Pressure range: 0.2-2.2MPA
                                    Rotation speed: 1500r/min    1800 r/min    2400 r/min    3000 r/min
                                    Ambient pressure :> 90KPa
                                    Ambient temperature: 50C-400C
                                    Relative humidity: ≤80%
                                    In abnormal conditions, greater diesel engine power is needed to match the pump.
                                     
                                    Configuration:
                                    1, pump: IS series of single-stage single-suction, S, SOW series 1-stage dual-suction, TSWA, D series multi-stage.
                                    2, diesel engine: 1-cylinder, 2-cylinder, 3-cylinder, 4-cylinder, 6-cylinder, 8-cylinder, 12-cylinder diesel engine.
                                    3, rotation speed: 1500r/min, 1800r/min, 2400r/min, 3000r/min.
                                    4, accessories: Filter muter, cooling system, fuel tank, seat, heat-exhaust water tank, storage battery, and charger. (Preheat system)
                                    5, control cabinet: microcomputer, PLC, sensors, automatic control cabinet..
                                     
                                    BORRA  Fire Pump System
                                    Diesel engine fire pump
                                    Main electric fire pump
                                    Jockey pump (pressure booster pump)
                                    Fire pump control panel


                                    Technical parameters:
                                     m3/hmr/min 
                                    XBC8.0/13.930-50-6084-80-752900IS80-50-250
                                    XBC7.0/13.047702900IS80-50-250A
                                    XBC6.0/12.244602900IS80-50-250B
                                    XBC8.5/11.742852900IS80-50-315B
                                    XBC11.0/13.471102900IS80-50-315A
                                    XBC12.5/13.930-50-60128-125-1232900IS80-50-315
                                    XBC5.0/27.860-100-12054-50-472900IS100-65-200
                                    XBC6.0/23.986602900IS100-65-250B
                                    XBC7.0/25.893702900IS100-65-250A
                                    XBC8.0/27.860-100-12087-80-752900IS100-65-250
                                    XBC10.0/25.0901002900IS100-65-315B
                                    XBC5.0/55.6120-200-24058-50-452900IS125-100-200
                                    XBC6.0/48.1173602900IS125-100-250B
                                    XBC12.5/27.860-100-120133-125-1182900IS100-65-315
                                    XBC8.0/55.6120-200-2087-80-722900IS125-100-250
                                    XBC12.5/55.6120-200-240133-125-1202900IS125-100-315
                                    XBC11.0/52.81901102900IS125-100-315A
                                    XBC9.2/48.1173922900IS125-100-315B
                                    XBC5.0/111240-400-46055-50-451450IS200-150-400
                                    XBC5.0/28100501450IS125-100-400
                                    XBC5.0/28200501450IS150-125-400
                                    XBC4.6/1030-36-4250-46-40145075TSWA×4
                                    XBC5.7/1030-36-4262-57-50145075TSWA×5
                                    XBC6.9/1030-36-4275-69-60145075TSWA×6
                                    XBC8.0/1030-36-4287-80-70145075TSWA×7
                                    XBC9.2/1030-36-42100-92-80145075TSWA×8
                                    XBC10.3/1030-36-42112-103-90145075TSWA×9
                                    XBC6.2/19.262-69-8064-62-561450100TSWA×4
                                    XBC7.8/19.262-69-8081-78-701450100TSWA×5
                                    XBC9.3/19.262-69-8097-93-841450100TSWA×6
                                    XBC10.9/19.262-69-80113-109-981450100TSWA×7
                                    XBC6.4/2572-90-10869-64-601450125TSWA×3
                                    XBC8.6/2572-90-10892-86-801450125TSWA×4
                                    XBC10.8/2572-90-108115-108-1001450125TSWA×5
                                    XBC6.0/43119-155-19165-60-551480150TSWA×2
                                    XBC9.0/43119-155-19197-90-821480150TSWA×3
                                    XBC12.0/43119-155-191129-120-1091480150TSWA×4
                                    XBC8.6/77.8190-280-34695-86-771480200D1-43×2
                                    XBC12.9/77.8190-280-346142-129-1151480200D1-43×3
                                    XBC12.0/125400-450-500123-120-1141480D450-60III×2
                                    XBC11.4/139450-500-550120-114-1081480D500-57×2
                                    XBC12.0/200550-720-850132-120-1081480D720-62×2
                                    XBC5.0/60150-216-26059-50-451480D216-25×2
                                    XBC7.5/60150-216-26088-75-671480D216-25×3
                                    XBC10.0/60150-216-260118-100-901480D216-25×4
                                    XBC12.5/60150-216-260147-125-1121480D216-25×5
                                    XBC6.5/134360-485-61271-65-561450250S65
                                    XBC9.0/219590-790-93693-90-821450300S90
                                    XBC7.8/210576-756-91886-78-70150300S90A
                                    XBC6.7/200540-720-90072-67-571450300S90B
                                    XBC5.8/219576-790-97265-58-501450300S58
                                    XBC5.0/204529-735-89355-50-421450300S58A
                                    XBC12.5/351850-1260-1660140-125-1001450350S125
                                    XBC11.2/328787-1181-1538120-112-861450350S125A
                                    XBC9.6/305697-1098-1363106-96-771450350S125B
                                    XBC7.5/351972-1260-144080-75-651450350S75
                                    XBC6.5/325900-1170-133270-65-561450350S75A
                                    XBC5.5/300813-1080-120259-55-461450350S75B
                                     *The above specifications are for reference only.We will customize according to customer needs.
                                    Fire Fighting Pump System 40-3000m3/H Flow Range for Sales
                                    Details Images

                                    Fire Fighting Pump System 40-3000m3/H Flow Range for SalesFire Fighting Pump System 40-3000m3/H Flow Range for Sales
                                    Company Work shop
                                    Fire Fighting Pump System 40-3000m3/H Flow Range for SalesOur Service
                                    1. Warranty: 1 year for the pump body, 3 month for the main working parts.

                                    2. Delivery: Delivery time will be on time as the contract. Usually, our company need 30 working  days for diesel engine pump, and for bare shaft pump, it takes 25 working days,

                                    3. Package: We use wood case to pack our pump, which is durable for ocean transport.

                                    4. On-sales Service: we will clear show you everything in fact when you place an order with us.
                                    We will 
                                    take photos or videos to show you our production situation,
                                    And updat the production situation to you.


                                    5. Quality: we will test our pump before delivery, and we will follow up the pump working conditions per three months when the pump put into use. we have free spare parts.


                                    Our Pump and Valve
                                    Fire Fighting Pump System 40-3000m3/H Flow Range for Sales

                                    Fire Fighting Pump System 40-3000m3/H Flow Range for Sales
                                    Fire Fighting Pump System 40-3000m3/H Flow Range for Sales

                                    Related Category

                                    Send Inquiry

                                    Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
                                    Click Refresh verification code

                                    Leave Your Message

                                    • Click Refresh verification code